Interlaced basalt fibers form numerous air pores. Porosity over 90% delivers fine heat insulation, as air is poor heat conductor. Thin and evenly arranged fibers optimize pore structure and curb heat transfer. Disordered fibers create heat passage and weaken insulation effect.
Optimal density ranges from 80 to 120kg/m³.
Low density: Loose fiber gaps cause air convection and fast heat loss
Excessively high density: Reduced air content raises thermal conductivity and lowers insulation capacity
Thermal resistance is proportional to thickness. Thicker board offers better heat preservation. Actual selection balances space limit, cost and structural load.
Loose splicing gaps form thermal bridges and accelerate heat leakage. Staggered laying and tight sealing are required to guarantee integral insulation efficiency.
Loose and displaced boards damage internal fiber structure and create air gaps, resulting in declining thermal performance. Firm installation maintains intact insulation structure.
Water fills pores and sharply increases heat transfer, for water thermal conductivity far exceeds air. Moisture also causes deformation and mildew, impairing long-term insulation effect. Waterproof protection is necessary in damp areas.
High temperature deteriorates binder performance and loosens fiber structure. Water freezing and thawing in pores damages fiber framework, permanently reducing insulation capacity.